Microsoft Download Center Archive
HPC Pack 2008 R2 SP2 Fix for 64-core Machine Support |
This update allows machines with 64 or more cores to be added to the HPC cluster
This update allows machines with 64 or more cores to be correctly scheduled and utilized by an HPC Pack 2008 R2-based cluster.
| Knowledge Base Articles: |
|---|
Files
Status: DeletedThis download is no longer available on microsoft.com. The downloads below are archives provided by the Internet Archive Wayback Machine from the Microsoft Download Center prior to January 2015. |
No files found
File sizes and hashes are retrieved from the Wayback Machine’s indexes. They may not match the latest versions of files hosted on Microsoft servers.
System Requirements
Operating Systems: Windows Server 2008, Windows 7, Windows Server 2008 R2, Windows HPC Server 2008 R2, Windows HPC Server 2008
An HPC Pack 2008 R2 / HPC Server 2008 R2 cluster
HPC Pack 2008 R2 Service Pack 2 must be installed
Installation Instructions
This hotfix need to be run on all nodes in the cluster with 64 or more cores, including Compute Nodes, Broker Nodes, Head Nodes, and Workstation Nodes.
To start the download, click the Download button and then:
1) Click Save to copy the download to your computer.
2) Run the download on the headnode.
Note: If you have a pair of HA headnodes, run the fix on the Active node and after failover occurs run the fix on the new Active node
3) Use the HPC Pack Node Template feature, or log on interactively, or use clusrun to to deploy the fix to the compute/broker/workstation nodes.
To use clusrun to deploy an HPC Pack 2008 R2 update on clusters that are running Service Pack 2, or higher:1.Copy the appropriate version of the update to a shared folder such as \\headnodename\SP2.2.In HPC Cluster Manager, view nodes by node group to identify a group of nodes that you want to update – for example, ComputeNodes. 3.Take the nodes in the node group offline. 4.Open an elevated command prompt window and type the appropriate clusrun command for the operating system of the patch, e.g.: clusrun /nodegroup:ComputeNodes \\headnodname\SP2\updatename.exe -unattend -SystemRebootNote: HPC Pack updates, other than Service Packs, do not get automatically applied when you add a new node to the cluster or re-image an existing node. You must either manually/clusrun apply the update after adding/reimaging a node or modify your node template to include a line to install the appropriate updates from a file share on your head node.
FamilyId: d3c5a6c0-ef31-4026-9b8e-06cc6f0e05ed